Vishakha Fibre Cement Board

Vishakha Fibre Cement BoardSolutions

Visaka’s priority is quality and strength. Therefore, it prides itself on excellence, superior technology, and most of all, the professional expertise that goes into making its products. Visaka’s products are undisputed recipients of appreciation for their affordability and durability. Visaka’s state-of-the-art Fibre Cement plant is a fully automated factory that incorporates new-age, sophisticated technology, ensuring consistency in physical properties and strength that surpasses the ISI standards.

ECONOMICAL SIZING & ESTIMATING FOR VISAKA CORRUGATED SHEETS & ACCESSORIES

Sizing For Roof:

  1. Let us assume the slope length is L metres
  2. To cover this length, a minimum of N number of sheets are; where N = L – 0.200/2.8 (a whole number) 
  3. Maximum lap loss is M metre Where M = (N-1) x 0.200
  4. Maximum sheet length required is P; where P = L + M => L + (N-1) x 0.200 (rounded off to next digit divisible by 0.25)
  5. Once P is obtained, sizing should be done keeping the number of sheets at N
  6. Check if the slope can be covered by (P – 0.25)
  7. Check that the number of purlins does not exceed – K; where K = L – ( a1 + a2) / 1.40 + 1 (a whole number); where a1 = distance between the eaves purling and the eaves edge in – Metre; where a2 = distance between the eaves purling and the eaves edge in – Metre.

For Wall Cladding :
Most economical length is 1.75 M, which allows a rail spacing of 1.6 M.

ISI SPECIFICATION TECHNICAL DATA

Standard lengths in (Metres)3.00, 2.75, 2.25, 2.00, 1.75, 1.50Tolerance (in mm)
+5 -10 +Free -0.5 +6 -2 +3 -5 +10 -5 +10 -5
Maximum unsupported overhang300 mm
Thickness6 mmMaximum Purlin Spacing for roofing1.4 M
Pitch146 mmMaximum Rail spacing for Vertical cladding1.7 M
Depth48 mmSection modulusZB:75 cm3 ZT:85 cm3
Overall Width1050 mmMoment of Rupture200 kg/cm2
Effective Width1010 mmRunning Metres per tonne78 (approx)
Minimum End lap150 mm (for slopes 180 and above)ColourLight Grey

Vishakha Fibre Cement Board Features

FIRE RESISTANCE

High degree of workability

Immune to water damage

TERMITE RESISTANCE

Provides sound insulation

RESISTANCE TO WATER

Low shrinkage

Low Maintenence

Leave a Comment

Your email address will not be published. Required fields are marked *